{"id":100066,"date":"2026-03-20T10:56:28","date_gmt":"2026-03-20T10:56:28","guid":{"rendered":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/producto\/transformador-reductor-de-208-vca-a-120-vca-con-entrada-hardwire-con-cable-de-uso-rudo-y-6-salidas-nema-5-20r-recomendado-para-ups-modelo-ols10kert5unema\/"},"modified":"2026-03-20T10:56:34","modified_gmt":"2026-03-20T10:56:34","slug":"transformador-reductor-de-208-vca-a-120-vca-con-entrada-hardwire-con-cable-de-uso-rudo-y-6-salidas-nema-5-20r-recomendado-para-ups-modelo-ols10kert5unema","status":"publish","type":"product","link":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/producto\/transformador-reductor-de-208-vca-a-120-vca-con-entrada-hardwire-con-cable-de-uso-rudo-y-6-salidas-nema-5-20r-recomendado-para-ups-modelo-ols10kert5unema\/","title":{"rendered":"Transformador Reductor de 208 Vca a 120 Vca, Con entrada Hardwire con Cable de Uso Rudo y 6 Salidas NEMA 5-20R, Recomendado para UPS modelo OLS10KERT5UNEMA"},"content":{"rendered":"<div style='width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;'> <!-- Secci\u00f3n de descripci\u00f3n --> <\/p>\n<div style='margin-bottom: 30px;'>\n<p style='font-size: 17px; line-height: 1.6; margin: 0 0 20px; color: inherit;'> El Transformador de Aislamiento CyberPower OLS10K2UXSTF&comma; proporciona una soluci\u00f3n efectiva para la protecci\u00f3n de dispositivos en centros de datos y aplicaciones cr\u00edticas. Su dise\u00f1o de aislamiento reduce el voltaje de 200-240V a 100-120V&comma; protegiendo equipos conectados de picos de corriente&comma; sobretensiones y fugas a tierra&comma; manteniendo la integridad operativa de los sistemas. <\/p>\n<\/p><\/div>\n<p> <!-- Caracter\u00edsticas Principales --> <\/p>\n<div style='margin-bottom: 30px;'>\n<h3 style='font-size: 24px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;'>Caracter\u00edsticas Principales<\/h3>\n<ul style='padding-left: 20px; font-size: 15px; color: inherit; margin-top: 15px;'>\n<li style='margin-bottom: 8px;'>Salida con capacidad completa para optimizar el rendimiento.<\/li>\n<li style='margin-bottom: 8px;'>Soporta frecuencias de 50\/60Hz&comma; garantizando compatibilidad internacional.<\/li>\n<li style='margin-bottom: 8px;'>Disyuntores de entrada y salida que se pueden restablecer para mayor facilidad de uso.<\/li>\n<li style='margin-bottom: 8px;'>Tensiones de salida m\u00faltiples simult\u00e1neas para adaptabilidad.<\/li>\n<li style='margin-bottom: 8px;'>Protecci\u00f3n contra sobrecalentamientos para una operaci\u00f3n segura.<\/li>\n<li style='margin-bottom: 8px;'>Factor de forma montaje en rack&comma; ideal para instalaciones en centros de datos.<\/li>\n<\/ul><\/div>\n<p> <!-- Secci\u00f3n de especificaciones --> <\/p>\n<div style='display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;'>\n<div style='flex: 1 1 300px; min-width: 280px;'>\n<div style='border: 1px solid rgba(150&comma; 150&comma; 150&comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column; height: 100%;'>\n<div style='padding: 15px; border-bottom: 1px solid rgba(150&comma; 150&comma; 150&comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;'>Especificaciones<\/div>\n<div style='padding: 15px; color: inherit; flex: 1 1 auto;'>\n<ul style='padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;'>\n<li style='margin-bottom: 5px;'><strong>Modelo:<\/strong> OLS10K2UXSTF<\/li>\n<li style='margin-bottom: 5px;'><strong>Voltaje nominal de entrada:<\/strong> 200&comma; 208&comma; 220&comma; 230&comma; 240 Vca<\/li>\n<li style='margin-bottom: 5px;'><strong>Rango de voltaje de entrada:<\/strong> 200 ~ 240 Vca<\/li>\n<li style='margin-bottom: 5px;'><strong>Frecuencia de entrada:<\/strong> 50&comma; 60 Hz<\/li>\n<li style='margin-bottom: 5px;'><strong>Corriente nominal de entrada:<\/strong> OLS10K2UXSTF &#8211; 50A<\/li>\n<li style='margin-bottom: 5px;'><strong>Capacidad de salida:<\/strong> 10000 VA\/10000 Watts (OLS10K2UXSTF)<\/li>\n<li style='margin-bottom: 5px;'><strong>Tensiones de salida:<\/strong> 100&comma; 110&comma; 115&comma; 120&comma; 200&comma; 208&comma; 220&comma; 230&comma; 240 V<\/li>\n<li style='margin-bottom: 5px;'><strong>Protecci\u00f3n contra sobrecargas:<\/strong> mediante disyuntor<\/li>\n<li style='margin-bottom: 5px;'><strong>Dimensiones:<\/strong> 433 x 87 x 660 mm<\/li>\n<li style='margin-bottom: 5px;'><strong>Peso:<\/strong> OLS10K2UXSTF &#8211; 55.6 kg<\/li>\n<li style='margin-bottom: 5px;'><strong>Altura del Rack Instalado:<\/strong> 2U<\/li>\n<li style='margin-bottom: 5px;'><strong>Temperatura de operaci\u00f3n:<\/strong> 0 ~ 40 \u00baC<\/li>\n<li style='margin-bottom: 5px;'><strong>Humedad relativa de almacenamiento:<\/strong> 0 ~ 90% sin condensaci\u00f3n<\/li>\n<li style='margin-bottom: 5px;'><strong>Certificaciones:<\/strong> NOM&comma; RoHS<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- Interfaces y Conectividad --> <\/p>\n<div style='flex: 1 1 300px; min-width: 280px;'>\n<div style='border: 1px solid rgba(150&comma; 150&comma; 150&comma; 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column; height: 100%;'>\n<div style='padding: 15px; border-bottom: 1px solid rgba(150&comma; 150&comma; 150&comma; 0.2); font-weight: bold; font-size: 18px; color: inherit;'>Interfaces y Conectividad<\/div>\n<div style='padding: 15px; color: inherit; flex: 1 1 auto;'>\n<ul style='padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;'>\n<li style='margin-bottom: 5px;'><strong>Tipo de conector de entrada:<\/strong> Regleta de conexiones permanentes<\/li>\n<li style='margin-bottom: 5px;'><strong>Salida(s) &#8211; Total:<\/strong> 8<\/li>\n<li style='margin-bottom: 5px;'><strong>Tipo de salida:<\/strong> Regleta de conexiones permanentes x 2&comma; NEMA 5-20R x 6<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- Aplicaciones y Casos de Uso --> <\/p>\n<div style='margin-bottom: 30px;'>\n<h3 style='font-size: 24px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; margin-bottom: 15px; color: inherit; opacity: 0.8;'>Aplicaciones y Casos de Uso<\/h3>\n<div style='display: flex; flex-wrap: wrap; gap: 20px;'>\n<div style='flex: 1 1 300px; min-width: 280px;'>\n<div style='border: 1px solid rgba(150&comma; 150&comma; 150&comma; 0.4); border-radius: 8px; overflow: hidden; padding: 15px; color: inherit;'>\n<p style='margin-bottom: 10px; font-size: 14px; color: inherit;'> Sistemas UPS en centros de datos que requieren reducci\u00f3n de voltaje y protecci\u00f3n m\u00e1xima contra anomal\u00edas el\u00e9ctricas. <\/p>\n<p style='font-size: 14px; color: inherit;'> Ambientes cr\u00edticos que demandan continuidad operativa y protecci\u00f3n contra sobretensiones en equipos sensibles. <\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<p> <!-- Separador final --> <\/p>\n<hr style='border: 0; border-top: 1px solid rgba(150&comma; 150&comma; 150&comma; 0.3); margin: 30px 0;'> <\/div>\n","protected":false},"excerpt":{"rendered":"<p>Transformador Reductor de 208 Vca a 120 Vca, Con entrada Hardwire con Cable de Uso Rudo y 6 Salidas NEMA 5-20R, Recomendado para UPS modelo OLS10KERT5UNEMA<\/p>\n","protected":false},"featured_media":100065,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1231],"product_tag":[677,142,1232],"class_list":{"0":"post-100066","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ups-no-break-energia-videovigilancia","7":"product_tag-cyberpower","8":"product_tag-energia","9":"product_tag-ups-no-break-2","11":"first","12":"instock","13":"sale","14":"shipping-taxable","15":"purchasable","16":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/wp-json\/wp\/v2\/product\/100066","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/wp-json\/wp\/v2\/comments?post=100066"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/wp-json\/wp\/v2\/media\/100065"}],"wp:attachment":[{"href":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/wp-json\/wp\/v2\/media?parent=100066"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/wp-json\/wp\/v2\/product_brand?post=100066"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/wp-json\/wp\/v2\/product_cat?post=100066"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/soydeaqui.ddns.net\/pachuca\/index.php\/wp-json\/wp\/v2\/product_tag?post=100066"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}